Provides comprehensive training on the installation, and repair of air conditioning and refrigeration systems, ensuring optimal performance and energy saving.
What is the value of optimum effective temperature in winter?
What does a TXV do?
7. EMT must be supported within what distance from an outlet box, junction box, device box, cabinet, conduit body or other terminations?
What state is the refrigerant in when leaving the compressor?
16. When a branch circuit feeds both noncontinuous and continuous loads, the circuit must be sized to accommodate 100% of the noncontinuous load plus what percent of the continuous load?
42. What is the minimum size conductor allowed for festoon lighting?
What does MAC stand for?
The name of part No. (1) is .......
Adding pressure to a liquid _______ its boiling point. Adding pressure to a vapor _______ its temperature.
When the heat stored in the body is ________ the human body feels comfortable.
What is the state of the refrigerant leaving the metering device in a refrigerator?
Which of the following would be carriedout to confirm a system contained no refrigerant?
a device, similar to a radiator, in which the refrigerant loses heat and changes state from a high-pressure gas to a high-pressure liquid as it dissipates heat to the surrounding air.
What is the job of the condenser?
- an A/C system component into which high-pressure liquid refrigerant flows and is temporarily stored and dehydrated, usually located between the condenser outlet and expansion valve.
34. What is the minimum load per each linear foot that must be allowed for show-window lighting?
Most escalator are designed with ____ mm wide steps which allow passengers to move comfortably when carrying luggage and shopping bags
elevators which are powered by a piston that travels inside a cylinder.
If contamination within an airconditioning system is suspected and a flushing procedure is to be carried outwhat component should also be changed?
The name of part No (3) is...........
The name of part No (4) is...........
46. The equipment grounding conductor contacts of receptacles and cord connectors must be grounded by:
When the hospital elevator can be made accessible at any other level which is accessible by means of an elevator with a minimum width of ____ mm
11. Holes in wood studs for cables must be drilled in the center of the stud and a distance from the nearest edge of not less than:
23. A 125-volt single-phase, 15- or 20-ampere receptacle be installed for the servicing of heating, air conditioning and refrigeration equipment. The receptacle outlet shall not be connected to the ___ side of the equipment disconnecting means
The elevators require regular inspection and maintenance and generally have a life of _____ years.
17. The branch-circuit load for a single 12-kilowatt (12 kW) electric range in a dwelling is:
3. Heavy-duty type lampholders are required on branch-circuits having a rating in excess of:
- to remove refrigerant from an A/C system and store it temporarily.
25. How are the lighting outlets installed at or near heating, air-conditioning, and refrigeration equipment in attics or underfloor spaces be controlled?
The state of Refrigerant at point A is ........
Why must refrigerant be recovered from the A/C system before any A/C parts are replaced?
29. Feeders containing a common neutral are permitted to supply how many sets of 5-wire feeders
14. EMT shall be supported at least every:
These lifts are self-contained and can be easily moved to where they are needed.
The state of Refrigerant at point C is ........
1. The cross-sectional area of three or more THW conductors ina conduit must not exceed what percent of the cross-sectional areaof the conduit?
How could you confirm the type ofrefrigerant present in an air conditioning system?
27. Feeders containing a common neutral are permitted to supply how many sets of 3-wire feeders?
40. When outside overhead wiring is used, with no messenger cable, what is the minimum size aluminum wire allowed for spans up to 50 feet?
In the evaporator, refrigerant is under very low pressure and is much colder than the air inside of the vehicle. Because of this, heat transfers from the ________ to the _______, causing the refrigerant to _______.
What is the temperature of the suction line if you touch it?
What is the value of the optimum effective temperature in summer?
Where does the low pressure liquid become a gas?
24. How many lighting outlets must be installed at or near heating, air-conditioning, and refrigeration equipment in attics or underfloor spaces?
What is a heat exchanger that induces condensation on the pressurized refrigerant, so that it changes phase from a gas to a liquid?
_________ are the devices that monitor their environment and record or send that information (data) to a computer processor.
- any of the various designs of fittings that allow service tools such as manifold gauges to be attached to an A/C system.
15. The total equivalent bend in rigid conduit between pull points (outlet to outlet, fitting to fitting, or outlet to fitting) shall not exceed:
The main components of the Air conditioning system are
The state of Refrigerant at point B is ........
What is the compressor known as?
a type of vertical transport equipment that efficiently moves people or goods between floors (levels, decks) of a building, vessel or other structures.Powered by Electric Motors
6. Branch circuits in two-family or multifamily dwellings required for the purpose of central lighting, central alarm, signal, communications, or other needs for public or commercial areas shall:
Designed to achieve the environmental requirements of the comfort of occupants and a process.
28. Feeders containing a common neutral are permitted to supply how many sets of 4-wire feeders?
Most common type of elevator. Elevator cars are pulled by means of rolling steel ropes over a deeply grooved pulley also called sheave.
Where would you expect to find a high pressure liquid within an AC system?
21. In what location must a 125-volt single-phase, 15- or 20-ampere receptacle be installed for the servicing of heating, air conditioning and refrigeration equipment?
Which component squeezes the gas?
a dynamic and responsive architecture that provides every occupant with productive, cost-effective and environmentally approved conditions through a continuous interaction among its basic elements; Places, Process, People, Management, Interrelation between them.
The air conditioning compressor _____________ vaporized refrigerant and allows it to flow to the condenser.
44. What is the maximum voltage allowed to supply listed electric-discharge lighting in residences, hotels, motels and similar occupancies?
The heat production from a normal healthy man when asleep is about _________
Exclusively used for carrying materials and shall not carry any person.
a valve that controls the flow of refrigerant, changing it from a high pressure liquid to a low pressure gas
A speed governor shall be provided in the escalator, the operation of which will cause the interruption of power to the driving machine should the speed of the steps exceed a pre-determined value, which shall be not more than ____% above the rated speed.
22. A 125-volt single-phase, 15- or 20-ampere receptacle be installed for the servicing of heating, air conditioning and refrigeration equipment must be installed within what distance from the equipment?
9. The NEC allows wall-switch controlled receptacles in dwelling units in lieu of lighting outlets in all habitable rooms except:
What is the state of the refrigerant leaving the evaporator?
In a typical system, within whichcomponent would the evaporation of refrigerant take place?
4. What is the maximum continuous load (in amperes) that can be used on a 240-volt, 20- ampere circuit using two No. 12 AWG conductors with THW insulation?
When leaving the compressor what state is the refrigerant in?
43. Receptacles installed on 15- and 20-ampere branch circuits must always be of what type?
are the moving step type lifts operating at constant speed between two levels in an inclined course for moving large number of people in a short time
What are the impacts on the environmentof fluorinated greenhouse gases?
- a chemical compound used in an A/C system to remove heat from the evaporator and transfer it to the condenser.
In what state is the refrigerant when it exits the condenser?
A chemical compound that is used as the heat carrier, which changes from gas to liquid and then back to gas in the refrigeration cycle
49. What location requires all 15- and 20-ampere receptacles to be protected with a ground fault circuit-interrupter?
41. Where outdoor pendant-type lampholders have terminals that puncture conductor insulation to make contact with the conductor, what type of wire must the conductor be?
The effective temperature increases with a decrease in relative humidity at the same DBT.
Which of the following provides the relationship between the optimum indoor effective temperature and optimum outdoor effective temperature?
The process of lowering the temperature of a substance below that of its surroundings
39. When outside overhead wiring is used, with no messenger cable, what is the minimum size copper wire allowed for spans up to 50 feet?.
Escalator Inspection are required once a year.
Which system has moving parts?
33. Where a feeder conductor supplies continuous loads, the rating of the overcurrent device shall not be less than the noncontinuous load plus 125% percent of the continuous load except?
12. Direct buried conductors and cables emerging from grade shall be protected by an enclosure or raceway a distance above ground of no less than:
13. Cable tray systems must not be used:
47. When existing nongrounding types of receptacles need replacing, what type of receptacle must be used?
What type of refrigerant is R134a?
32. Where a feeder conductor supplies continuous loads, the rating of the overcurrent device shall not be less than the noncontinuous load plus what percent of the continuous load?
35. What percent of fixed electric space heating loads must be used in calculating the total connected load on a branch circuit or feeder?
An electric motor shall not drive more than _____ escalator.
48. When receptacles are connected to circuits having different voltages, frequencies, or types of current (ac or dc) on the same premises, what precautions must be taken?
45. Receptacles and cord connectors that have equipment grounding conductor contacts must have those contacts:
18. A 20-ampere laundry circuit is always required in each:
What does a Thermal Xpansion Valve do?
What is the temperature of the line at the outlet of the expansion device if you touch it?
10. Insulated conductors of No. 6 or smaller intended for use as grounded conductors in a circuit must be either of the following colors:
If contamination within an air conditioning system is suspected and a flushing procedure is to be carried out what component should also be changed?
50. Which one of the following is not allowed to supply branch circuits?
What is the job of the evaporator?
Which of the following is true about the optimum effective temperature for human comfort?
Assuming normal atmospheric pressure atwhat temperature would R134a boil?
The machine room and the escalator hoistway shall be finished with mortar or other materials so as to prevent concrete dust.
Every occupant of a high-rise commercial building needs to take lifts at least _____ times a day, in the morning, during lunch and after office hours
2. What is the minimum size THW copper conductor that may be used on a 30-ampere branch circuit?
The Simple Refrigeration cycle consists of .....
Where would you expect to find a highpressure liquid within an AC system?
What is the temperature of the discharge line if you touch it.
What happens in the first 1/3 of the condenser?
What is the job of the expansion device?
31. Which one of the following voltages is not standard?
The name part (2) is ...........
20. How many receptacle outlets are required in a residential garage?
38. What demand factor is allowed for a commercial kitchen with one electric appliance?
The state of Refrigerant at point D is ........
How would you know the air con gas hasbeen fully recovered from the system?
8. All 125-volt, single-phase, 15- or 20-ampere receptacle outlets installed in bathrooms of dwelling units always require:
Which of these is NOT a refrigerant used in automotive A/C sytems?
30. Service conductors run above the top level of a window shall be permitted to be less than the _____ requirement.
This removes pressure from the liquid refrigerant to allow expansion or change of state from a liquid to a vapor in the evaporator
What is the temperature of the liquid line if you touch it?
What do you call the part of a refrigeration system in which the refrigerant absorbs heat and changes from a liquid to a gas.
How should R134a be stored to meet safetyrequirements?
Automatic centralized control of a building's HVAC and otherinterrelated system.
Which of the following does not mainly a factor of dependency for the degree of warmth or cold?
The R 134a cylinder color is ........
- a heat exchanger, in which low-pressure refrigerant flows and changes state, absorbing heat from the surrounding air and cools the passenger compartment.
26. The lighting outlets installed at or near heating, air-conditioning, and refrigeration equipment in attics or underfloor spaces be controlled by a switch. Where must the switch be located?
Which engine driven device compresses refrigerant and pumps it through the air conditioning system?
37. If the apartment complex is expanded to include a total of 40 units with a 12 kW range in each, what is the total kW rating for all the ranges that must be used in calculating the electric service?
The rated speed Of Escalators shall be not more than 0.64 m/s except that higher speeds may be permitted subject to the approval of the enforcing authority.
5. A 30-ampere branch circuit may supply fixed lighting units in:
a compound typically found in either a fluid or gaseous state. It readily absorbs heat from the environment and can provide refrigeration or air conditioning when combined with other components such as compressors and evaporators.
What is the state of the refrigerant entering the compressor?
What does COSHH stand for?
36. If four 12 kW electric ranges are used in a four-unit apartment complex, what is the total kW rating that must be used for all of these ranges in calculating the electric service?
19. How many receptacles are required in a residential hallway 12 feet in length?
To keep up this site, we need your assistance. A little gift will help us alot.
Donate- The more you give the more you receive.
Related SubjectRefrigeration Service
Heating, Ventilation, Air Conditioning and Refrigeration
TikTok Resumes Service in the United States
Kamala Harris: Insights into the Vice President’s Life and Work
Public Service
Hospitality Management
Hotel Management
Food Service Management
Credit and Collection
Nursing Interventions: Ineffective Breathing Pattern
Respiratory Care Science
Kitchen and Bath Specialty
Software Development
Maintenance Technology
Industrial Electronics Maintenance
Computer Support Technician
System Analysis Design and Development
Property Management System
Information Systems Operations and Maintenance
Software Engineering 2
Driver Device
Fine Arts
Network Administration
Electronics Engineering Technology
Data Communications and Networking
Data Communications and Networking 3
Shopee Cashback Voucher
Temu $0 Shipping Fee
Amazon 75% Off Discounts